COILS with USB BLACK NET KEY
SETUP and CONFIGURATION
USB NET KEY SETUP
The USB NET key can be connected to any Usb port present on the computer. During installation of the key the operating system could ask for the specific drivers.
The drivers are in the following folder “Driver_Installation_SDI”.
SETUP and CONFIGURATION (SERVER SIDE)
Setup of the USB NET key can be done on any computer connected to the network and the installation of the software UNILAB COILS6 is not necessary.
To configure the service launch the file “scc.exe” which is in folder “Control_Central_SCC”.
The following mask will appear:
click on the “Multilan Server” panel:
Click on the button “Installa” in the section “Configurazione per server come servizio Windows”:
Check the voice “TCPIP” and specify a port in the field “Porta” (usually 16567) and a timeout in the field “timeout” (usually 60):
Finish the procedure by clicking the button “Applica” and then ok then “OK” or directly the button “OK”.
SETUP and CONFIGURATION (CLIENT SIDE)
The setup Client side needs to be done on every computer where You want to install and use UNILAB COILS6.
To configure the service launch the file “scc.exe” folder “Control_Central_SCC”.
The following screen will be displayed:
Hit the button “Aggiungi” or "Add":
Choose “TCPIP” and push “OK”:
Specify in the field “Nome server or the IP address” the name of the computer (or in alternative IP address) where It has been configured for the SERVER service (in the following example “thefuture”) and in the field “Porta server” the port configured in the “SERVER” service(usually 16567).
Check the voice “Usa sempre il protocollo locale come ultima risorsa” as in the drawing.
End the procedure hitting the button “Applica” and then “OK” or directly the button “OK”.
At this point It is possible to use UNILAB COILS.
BELOW YOU CAN FIND REQUIRED SOFTWARES "BLACK_NET_Installation.zip"